Firetrace Fire Suppression Systems

Industrial machinery, electrical switchgear, and CNC machines require immediate suppression at the origin of combustion. As an authorized Platinum Partner of Firetrace, Suppression Systems, Inc. (SSI) engineers, installs, and services self-activating pneumatic fire suppression packages across Pennsylvania, New Jersey, New York, and the Mid-Atlantic.

6-Hour Direct Dispatch Territory: Factory-certified technicians dispatched across PA, NJ, NY, DE, MD, VA, and Eastern OH from Breinigsville, PA.

Codes & Manufacturer Certifications

Firetrace pre-engineered systems comply strictly with NFPA 2001 (Clean Agent Systems) and NFPA 12 (Carbon Dioxide Systems), carrying global listings from FM Approvals and Underwriters Laboratories (UL). Furthermore, all systems integrate with our Autocall addressable fire alarm control panels. For facilities managing combustible dust or spark hazards in ductwork, explore our industrial explosion protection & Flamex spark detection systems.

How Pneumatic Tubing Stops Enclosed Fires

Standard total flooding clean agent systems protect the room envelope, but they cannot penetrate closed machine enclosures or electrical chassis quickly enough to stop localized ignition. Specifically, Firetrace solves this by routing flexible, red polymer detection tubing directly inside high-risk machinery spaces.

Because the tubing maintains continuous pneumatic pressure, it reacts instantly when temperatures exceed 212°F. Specifically, the heat causes the tube to burst at the exact point of ignition.

Consequently, the system operates completely independent of building power, auxiliary wiring, or optical sensors. This ensures total protection during facility blackouts and severe electrical disruptions.

Direct vs. Indirect Configurations

  • Direct Low-Pressure (DLP): The ruptured tube acts as the discharge nozzle, spraying clean agent directly onto the fire within 3 seconds.
  • Indirect Low-Pressure (ILP): The tubing acts as a sensor, opening a differential valve to discharge larger agent volumes through fixed stainless steel nozzles.
  • 100% Mechanical Reliability: Zero moving electrical parts, zero batteries, and zero false electrical activations.
  • Targeted Asset Protection: Extinguishes small equipment fires without shutting down the entire plant floor.

Engineered Firetrace Micro-Environment Applications

Targeted protection systems engineered for mission-critical enclosures where electrical short circuits or flammable cutting oils create severe localized hazards.

CNC Machine Tools & Robotics

High-speed milling and Swiss turning machines utilizing flammable straight-oil coolants generate intense friction heat that can ignite spontaneously inside cutting cabinets.

  • Snuffs oil-mist fires within machine cabinets
  • Protects multi-axis robotic arms and tool changers
  • Leaves zero abrasive powder residue on tooling
  • Allows operators to resume production in hours

Electrical Enclosures & Switchgear

Aging components, loose terminal connections, and localized arc faults can ignite electrical panels, threatening adjacent motor control centers and facility power supplies.

  • Direct DLP tubing weaves between busbars and breakers
  • Non-conductive clean agent protects live circuits
  • Eliminates catastrophic switchgear loss
  • Meets NFPA 2001 and insurance compliance rules

Fume Hoods & Chemical Cabinets

Research laboratories, pharmaceutical cleanrooms, and chemical mixing benches handle volatile solvents that can flash into flame inside high-airflow exhaust ducts.

  • Continuous thermal monitoring through duct paths
  • Suppresses Class B solvent and vapor fires
  • Non-toxic agents safe for laboratory spaces
  • Interlocks to shut off duct exhaust dampers
System Type Actuation Method Extinguishing Agents Typical Volume Protected Ideal Industrial Application
Direct Release (DLP) Pneumatic Tubing Rupture Point FK-5-1-12 / FM-200 / CO2 Up to 250 ft³ Electrical panels, server racks, small battery cabinets
Indirect Release (ILP) Pneumatic Sensor + Piped Nozzles FK-5-1-12 / FM-200 / CO2 Up to 1,500 ft³ Enclosed CNC milling centers, EDM machines, fume hoods
Total Flooding Clean Agent Electronic Panel + Area Smoke Detection ECARO-25 / FK-5-1-12 Entire Rooms (> 5,000 ft³) Data halls, control rooms, archives
FirePro® Aerosol Solid FPC Compound Generator Condensed Potassium Salts Compartments & Vaults Non-pressurized battery energy storage (BESS)

Firetrace Technical FAQs

Review key technical considerations regarding pneumatic tubing physics, agent selection, and maintenance.

How does Firetrace pneumatic detection tubing work?

Firetrace systems utilize flexible polymer tubing pressurized with nitrogen. When exposed to heat or flames exceeding 212°F to 248°F, the tubing ruptures at the hottest point. In Direct systems, extinguishing agent discharges immediately through the burst hole. In Indirect systems, the pressure drop opens a valve to discharge agent through fixed nozzles.

Do Firetrace systems require electricity to operate?

No. Firetrace systems function entirely on mechanical pressure and pneumatic release. Therefore, they remain fully operational during complete facility power failures, electrical short circuits, and brownouts.

What is the difference between Direct and Indirect Firetrace systems?

Direct release systems use the ruptured detection tube itself as the delivery nozzle, making them ideal for compact electrical enclosures. Indirect release systems use the tubing strictly as a sensor, discharging larger volumes of clean agent through piped distribution nozzles for complex machinery like multi-axis CNC mills.

What does SSI’s Platinum Partner of Firetrace status mean for customers?

As an authorized Platinum Partner of Firetrace, SSI maintains factory-trained technicians, priority manufacturer allocation, dedicated stock of tubing and cylinders in Breinigsville, PA, and certified 24/7 emergency service support throughout our 6-hour territory.

Monthly Life-Safety Bulletins

Subscribe to SSI Monthly Insights

Receive technical bulletins on CNC machine protection, NFPA 2001 clean agent rules, and industrial maintenance tips.

Request Information

“*” indicates required fields

If this is an emergency, please call our 24/7 service line at 800-360-0687

"*" indicates required fields

This field is for validation purposes and should be left unchanged.
Name*
Company Address*
Service*